Horiba Water Quality Analyzer Devision

 
 

  

¹°Àº Àΰ£À» Æ÷ÇÔÇÑ Áö±¸»ó¿¡ Á¸ÀçÇÏ´Â »ý¸íüÀÇ »ý¸í À¯Áö¿¡ ¾ø¾î¼­´Â ¾ÈµÇ´Â ¾ÆÁÖ Áß¿äÇÑ °ÍÀÔ´Ï´Ù. ±×·¸±â ¶§¹®¿¡ ¼öÀÚ¿ø °ø±Þ¿ø¿¡ ´ëÇÑ Áö´ëÇÑ °ü½É°ú ÇÔ²² ¹ÏÀ» ¼ö ÀÖ´Â ¼öÁú ºÐ¼®¿¡ ´ëÇÑ ¿ä±¸°¡ ´Ã¾î³ª°í ÀÖ´Â »óÅÂÀÔ´Ï´Ù. Sensor Technology °³¹ßÀÇ ¼±µÎ ÁÖÀÚÀÎ HORIA´Â ÀÌ·¯ÇÑ ´Ù¾çÇÑ ¿ä±¸¸¦ ÃæÁ·½Ãų ¼ö ÀÖ´Â ´Ù±â´É ¼öÁú ºÐ¼®±â¸¦ °³¹ßÇÏ°Ô µÇ¾ú½À´Ï´Ù. ÃÖ´ë 13°¡Áö Ç׸ñºÐ¼®, Àå±â°£ ¿¬¼Ó µ¥ÀÌÅÍ ÀúÀå ±â´É ¹× ³ôÀº ¼ö¾ÐÀÇ È¯°æ¿¡¼­µµ ÃøÁ¤ °¡´ÉÇÑ ¼ÒÇüÀÇ ¼öÁú ºÐ¼®±â ÀÔ´Ï´Ù.

ÁÖ¿ä±â´É ¹× Ư¡

 Up to one month Data logging

¼¾¼­¿¡ ³»ÀåµÈ ¸Þ¸ð¸® ±â´ÉÀº ÃøÁ¤ µ¥ÀÌÅ͸¦ ÃÖ´ë ÇÑ´Þ°£ ¿¬¼ÓÀ¸·Î ÀúÀåÀÌ °¡´ÉÇÕ´Ï´Ù(15min ¸¶´Ù ÀúÀå½Ã) ÃøÁ¤°ªÀº ÀÚµ¿ ¼³Á¤¿¡ ÀÇÇØ ¿øÇÏ´Â °£°½À» µÎ°í ÀúÀåÀÌ °¡´ÉÇÕ´Ï´Ù.
ÃøÁ¤ÀÚ´Â º¸°üµÈ µ¥ÀÌÅ͸¦ PC¸¦ ÀÌ¿ë °ü¸® Çϰųª ÇÁ¸°ÅÍ°¡ °¡´ÉÇÕ´Ï´Ù


 
Measurement at depths as low as 100 meters
¿ì¼öÇÑ ³»±¸¼º ¹× ³»¾Ð¼ºÀ» Áö´Ñ »õ·Î¿î ¼¾¼­ÀÇ °³¹ß¿¡ ÈûÀÔ¾î ÃÖ´ë ¼ö½É 100m ±îÁö »ç¿ëÀÌ °¡´ÉÇÕ´Ï´Ù. ÀÌ´Â ÃøÁ¤Àå¼Ò¿¡ ±¸¾Ö¹ÞÁö ¾Ê°í ¾÷¹« ¼öÇàÀÌ °¡´ÉÇÔÀ» ÀǹÌÇϸç, °­, È£¼ö, ½ÀÁö, ¹Ù´Ù±îÁöµµ ±× ½ÇÇè ¿µ¿ªÀ» ³ÐÈú ¼ö ÀÖ½À´Ï´Ù. 


 
Simultaneous measurement of 13 parameters
ÃøÁ¤ Ç׸ñÀ» Probe¿¡ µû¶ó 10¶Ç´Â ÃÖ´ë 13Ç׸ñÀÇ ÃøÁ¤ÀÌ °¡´ÉÇϸç ÀÌ´Â ±âÁ¸ ±â±âµé°ú ºñ±³ÇÏ¿© ªÀº ½Ã°£¿¡ ºÐ¼®¼öÇà ´É·ÂÀ» °®Ãß°í ÀÖÀ¸¸ç ¸ðµç ¼öÁúºÐ¼® ¿¬±¸¿¡ Àû¿ë °¡´ÉÇÑ ±â±â·Î °­·Â ÃßõÇÕ´Ï´Ù.


 
System enables GPS and numerous other data processing mechanisms


GPS (Global Positioning System)¸¦ ÅëÇÑ µ¥ÀÌÅÍ Ã³¸® °¡´É (option) - ÃøÁ¤ °á°úÀÇ ½ºÅ©¸° µð½ºÇ÷¹ÀÌ ¹× 3-D ó¸® °¡´É

 

 
One Touch Calibration makes work easy

5°¡Áö Ç׸ñ-pH, Cond, D.O, ¼ö½É, º¸Á¤À» ÈÖÇØ ¹öÆÛ 4¿¡ Probe¸¦ ´ã±×°í ¹öÆ° Èù¹ø Á¶ÀÛÀ¸·Î º¸Á¤À» ¸¶Ä¥ ¼ö ÀÖ½À´Ï´Ù. ÀϺΠÀÌ¿ÂÀÇ °æ¿ì ¿ª½Ã Çϳª·Î º¸Á¤ÇÒ ¼ö ÀÖ½À´Ï´Ù. ¹°·Ð º¸´Ù Á¤¹ÐÇÑ ÃøÁ¤ÀÌ ÇÊ¿äÇÑ °æ¿ì 2Á¡ º¸Á¤ÀÌ °¡´ÉÇÕ´Ï´Ù.


Application Field

 

 

 

 

Çؼö

»ýÈ° ¿À Æó¼ö

È£¼Ò¼ö

°ø¾÷Æó¼ö

 

 

 

 

´ï

³ó¾÷¿ë¼ö

ÁöÇÏ°üÁ¤

¾ç¾îÁ¾¹¦Àå

 Ordering Guide

Probe Model

Ç׸ñ¼ö

ÃøÁ¤Ç׸ñ

U-22XD(set±¸¼º)

10 °¡Áö

pH, Àüµµµµ, D.O, ¿°µµ, TDS, ÇؼöºñÁß, ¿Âµµ, Źµµ, ¼ö½É, ORP

W-22P (¹ÌÅÍ ÄÉÀÌºí º°µµ±¸¼º)

W-23P (¹ÌÅÍ ÄÉÀÌºí º°µµ±¸¼º)

13 °¡Áö

pH, Àüµµµµ, D.O, ¿°µµ, TDS, ÇؼöºñÁß, ¿Âµµ, Źµµ, ¼ö½É, ORP
+

3ÀÌ¿Â ¼±ÅÃ(NO3-, Cl-, Ca2+, F-, K+, NH4+)

 U-22XD(set±¸¼º)

Á¦Ç°¹øÈ£

Á¦Ç°¸í(±Ô°Ý) ´ÜÀ§
U-22-10m U-22 Water quality monitoring system,
10m ÄÉÀ̺í
set
U-22-2m U-22 Water quality monitoring system,
2m ÄÉÀ̺í
set
U-22-30m U-22 Water quality monitoring system,
30m ÄÉÀ̺í
set

 ¼¾¼­ º»Ã¼ ºÐ¸®Çü

Á¦Ç°¹øÈ£ Á¦Ç°¸í(±Ô°Ý) ´ÜÀ§
W-23P Dual Probe, 13 Ç׸ñ ÃøÁ¤, ¼ö½É 100m ÃøÁ¤ ea
W-22P Single Probe, 10 Ç׸ñ ÃøÁ¤, ¼ö½É 100m ÃøÁ¤ ea

Optional Accessory


Á¦Ç°¹øÈ£

Á¦Ç°¸í(±Ô°Ý)

´ÜÀ§

W-010C 10m detachable cable ea
W-030C 30m detachable cable ea
6230 pH sensor ea
6280 pH/ORP Sensor ea
5460 DO sensor ea
6531 Nitrate Ion Sensor ea
6522 Chloride Ion Sensor ea
6533 Calcium Ion Sensor ea
5012 Ammonia sensor ea
6530 Fluoride Ion Sensor ea
6532 Potassium Ion Sensor ea
W-2030 Carrying Case 30mÀÌ»ó ÄÉÀ̺í¿ë ea
W-2010 Carrying Case 10mÀÌÇÏ ÄÉÀ̺í¿ë ea
W-100C 100m detachable cable ea
W-2100 Flow Through Cell, W-22P¸¸ »ç¿ë, 0.1-0.5l/min ea
U-2001 Extension Unit ea
U-2002 System Unit ea
W-2000 Control Unit, Multi-probe & cableÀº º°µµ ÁÖ¹® ea
w-2200 Multi-Probe Guard ea

  

 U-20XD Series Specification
 

 

U-22XD SET

W-22XD

W-23XD

Control Unit

Water proof construction

IP-67

( )
option

( )
option

Multi-Probe *1

Measurement temperature

0~55°C

(to30m)

Storage temperature

-5~60°C

Measurement depth *2

to 100 m

Maximum probe size

95 mm

Probe length

430 mm

Continuous use *3

30days

Data logging

Manual data memory (2880 items)

Automatic calibration

pH
*Two-point calibration
*Automatic temperature compensation

Measurment Principle

Glass electrode method

( )
option

( )
option

Range

pH 0~14

Resolution

0.01 pH

Repeatability

±0.05 pH

Accuracy

±0.1 pH

Dissolved oxygen
*Salt correction
(0 to 40 ppt /automatic)
*Automatic temperature compensation

Measurment Principle

Diaphragm galvanic battery method

( )
option

( )
option

Range

0~19.99 mg/L

Resolution

0.01 mg/L

Repeatability

±0.1 mg/L

Accuracy

±0.2 mg/L

Conductivity
*Auto range
*Automatic temperature
conversion (25°C)
*SI units

Measurment Principle

4 AC electrode method

Range

0~9.99 S/m

Resolution

0.1%F.S

Repeatability

±1%

Accuracy

±3%

Salinity

Measurment Principle

Conductivity conversion

Range

0~4%

Resolution

0.01%

Repeatability

±0.1%

Accuracy

±0.3%

Total Dissolved Solids (TDS)
*Conversion factor setting

Measurment Principle

Conductivity conversion

Range

0~100 g/L

Resolution

0.1%F.S

Repeatability

±2 g/L

Accuracy

±5 g/L

Seawater specific gravity
*Display t, 0, 15

Measurment Principle

Conductivity conversion

Range

0~50 t

Resolution

0.1 t

Repeatability

±2 t

Accuracy

±5 t

Temperature

Measurment Principle

Thermistor method

Range

0~55°C

Resolution

0.01°C

Repeatability

±0.3°C

Accuracy

±1.0°C

Turbidity
*Unit selection

Measurment Principle

Penetration and scattering method

Range

0~800 NTU

Resolution

0.1 NTU

Repeatability

±3%

Accuracy

±5%

Water depth

Measurment Principle

Pressure method

Range(NTU or mg/L)

0~100m

Resolution

0.1 m

Repeatability

±3%

Accuracy

±5%

Oxidation reduction potential(ORP)

Measurment Principle

Platinum electrode method

( )
option

( )
option

Range

±1999 mV

Resolution

1 mV

Repeatability

±5 mV

Accuracy

±15 mV

Ion
*Auto range

Measurment Principle

Ion electrode method

-
-

( )
option

( )
option

( )
option

Resolution

0.1%F.S

Repeatability

±5%

Accuracy

±10%

Nitric acid ion

Range

NO3-: 0.62~62,000 mg/L(pH 3~7)

Chloride ion

Cl-: 0.4~35,000 mg/L(pH 3~11)

Calcium ion

Ca2+: 0.4~40,080 mg/L(pH 5~11)

Fluoride ion

F-: 0.02~19,000 mg/L(pH4~10:20 mg/L)

Potassium ion

K+: 0.04~39,000 mg/L(pH5~11:3.9 mg/L)

Ammonia

NH3: 0.1~1,000 mg/L(pH 12 or more)

Simultaneously measurable parameters

   

10

10

13

 

  | Tel: 02-2057-2007(´ë) | FAX: 02-2057-2009
Copyright@2004 Donglim Science Co.,Ltd. All right reserved.